Smoke alarm regulations for landlords in England

Smoke alarm regulations in England require a landlord to fit a smoke alarm on every storey with living accommodation and a carbon monoxide alarm in every room with a fixed combustion appliance other than a gas cooker, check them on the first day of each new tenancy and repair them when told they are faulty.[1]

Not a government website. Not legal advice. England only. We are a private company, not affiliated with GOV.UK, the Ministry of Housing, Communities and Local Government or any council. Registration is done on the official service.

Smoke alarms: one on every storey

A rental home in England needs at least one smoke alarm on every storey that has a room used wholly or partly as living accommodation; bathrooms and lavatories count.[1] Guidance says alarms usually go on the ceiling of a hall or landing, following the maker’s instructions, and that a heat detector is not a replacement for a smoke alarm.[2] A mezzanine is not treated as a storey.[2]

How many alarms does my rental need?

Count the storeys with living accommodation and the rooms with a boiler, fire or stove.

Boilers, gas or oil fires, log burners and other stoves. Bathrooms count as rooms.

Alarms required

2 smoke + 2 CO

The legal minimum; the regulations do not set the type, but government guidance says sealed-for-life batteries are the better option.

Smoke alarms (at least)2 — one on each storey with living accommodation, usually on the ceiling of the hall or landing
Carbon monoxide alarms (at least)2 — one in each room with a fixed combustion appliance, at head height 1–3 m from it
Check every alarm works on1 December 2026 (the day the tenancy begins); keep a record, for example in the signed inventory
If the council serves a remedial noticeFit, repair or check the alarms within 28 days, or face a penalty of up to £5,000

Runs in your browser; nothing is sent. England only. Licensed HMOs meet the same duties through their licence conditions.

On this page
  1. Smoke alarms: one on every storey
  2. How many alarms does my rental need?
  3. Carbon monoxide alarm regulations
  4. Checks and repairs
  5. Fire safety regulations for landlords beyond alarms
  6. Enforcement: remedial notice and £5,000 penalty
  7. FAQ
  8. Sources

Carbon monoxide alarm regulations

A carbon monoxide alarm is required in every room used as living accommodation that contains a fixed combustion appliance, other than a gas cooker.[1] A fixed combustion appliance burns fuel of any kind to make heat: gas or oil boilers, gas fires, coal fires and log burners.[2]

Does this room need a CO alarm?
Room hasCO alarm?
Gas combi boiler (kitchen or bathroom)Yes
Wood or multi-fuel stoveYes
Oil boilerYes
Gas cooker onlyNo
Decorative fireplace that does not workNo
Electric heating onlyNo

Source: regulation 4 and the government Q&A booklet.[1][2] Place CO alarms at head height, 1 to 3 metres from the appliance.[2] Gas appliances also need their yearly gas safety check.[4]

Checks and repairs

The landlord checks that each alarm works on the day a new tenancy begins and repairs or replaces an alarm after the tenant reports it faulty.[1]

  • Day one: test every alarm; one way to prove it is to have the tenant sign the inventory recording the test.[2]
  • During the tenancy: tenants test the alarms; the landlord should show them how and share the instructions.[2]
  • After a report: check and repair or replace the alarm as soon as reasonably practicable.[1]
  • No access: write to the tenant, offer convenient times and keep a record of each attempt; you are not expected to go to court for access.[2]

Shared homes where the tenant lives with the landlord or the landlord’s family, long leases, student halls, hotels and care homes are excluded.[2]

Fire safety regulations for landlords beyond alarms

Alarms are one part of a landlord’s fire safety duties; the others are escape routes, safe furniture and extra rules for HMOs and flats.[5][6]

Fire safety duties of a private landlord in England (GOV.UK)
DutyWhat it means
AlarmsSmoke alarm on each storey; CO alarm by fixed combustion appliances (the rules above)
Escape routesThe tenant has access to escape routes at all times
Furniture and furnishingsAnything you supply is fire safe
Large HMOFire alarms and extinguishers; see the HMO licence rules
FlatsFollow the fire safety regulations for purpose-built blocks and houses converted into flats
RepairsFire safety issues are always the landlord’s repair

Sources: GOV.UK guidance for tenants and landlords.[5][6] Fire hazards are also one of the risks a council checks under the housing health and safety rating system.[6]

Enforcement: remedial notice and £5,000 penalty

Councils enforce the alarm regulations with a remedial notice and a penalty of up to £5,000 per breach.[3][2] The notice gives you 28 days from service to fit, repair or check the alarms, and 28 days to make written representations.[3] The alarm check is one of the day-one items in the landlord checklist; the free landlord compliance calendar keeps the gas, EICR and EPC dates next to it.

Frequently asked questions

What do the smoke and carbon monoxide alarm regulations require?

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015, amended from 1 October 2022, require a smoke alarm on each storey with living accommodation, a carbon monoxide alarm in each room with a fixed combustion appliance (not a gas cooker), a check on the first day of a new tenancy, and repair or replacement after a report.[1][2]

Do smoke alarms in a rental have to be hard-wired?

No. The regulations do not set the type. Government guidance recommends alarms that meet BS 5839-6, and sealed-for-life batteries rather than replaceable ones.[2]

What do the carbon monoxide alarm regulations say about gas boilers?

Since 1 October 2022 a CO alarm is needed in any room used as living accommodation with a fixed combustion appliance, including gas boilers, oil boilers and log burners. Only gas cookers are excluded.[1][2]

Who changes the batteries in a rented home?

The tenant is advised to replace batteries; if the alarm still does not work, or they cannot do it, they report it and the landlord must repair or replace it as soon as reasonably practicable.[2][1]

What is the fine for not having smoke alarms?

The council serves a remedial notice with 28 days to comply; if the landlord does not comply, it can charge up to £5,000 per breach.[3][2]

Sources

  1. Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulation 4 · legislation.gov.uk, 2026-11-15
  2. Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022: guidance for landlords and tenants · Ministry of Housing, Communities and Local Government, 2022-07-29
  3. Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulations 5 and 8 (remedial notice and penalty) · legislation.gov.uk, 2026-11-15
  4. Gas Safety (Installation and Use) Regulations 1998, regulation 36 · legislation.gov.uk, 2026-11-15
  5. Private renting: your landlord’s safety responsibilities · GOV.UK, 2026-11-15
  6. Renting out your property: landlord responsibilities · GOV.UK, 2024-12-12