Smoke alarms: one on every storey
A rental home in England needs at least one smoke alarm on every storey that has a room used wholly or partly as living accommodation; bathrooms and lavatories count.[1] Guidance says alarms usually go on the ceiling of a hall or landing, following the maker’s instructions, and that a heat detector is not a replacement for a smoke alarm.[2] A mezzanine is not treated as a storey.[2]
How many alarms does my rental need?
Count the storeys with living accommodation and the rooms with a boiler, fire or stove.
Alarms required
2 smoke + 2 CO
The legal minimum; the regulations do not set the type, but government guidance says sealed-for-life batteries are the better option.
| Smoke alarms (at least) | 2 — one on each storey with living accommodation, usually on the ceiling of the hall or landing |
|---|---|
| Carbon monoxide alarms (at least) | 2 — one in each room with a fixed combustion appliance, at head height 1–3 m from it |
| Check every alarm works on | 1 December 2026 (the day the tenancy begins); keep a record, for example in the signed inventory |
| If the council serves a remedial notice | Fit, repair or check the alarms within 28 days, or face a penalty of up to £5,000 |
Runs in your browser; nothing is sent. England only. Licensed HMOs meet the same duties through their licence conditions.
On this page
Carbon monoxide alarm regulations
A carbon monoxide alarm is required in every room used as living accommodation that contains a fixed combustion appliance, other than a gas cooker.[1] A fixed combustion appliance burns fuel of any kind to make heat: gas or oil boilers, gas fires, coal fires and log burners.[2]
| Room has | CO alarm? |
|---|---|
| Gas combi boiler (kitchen or bathroom) | Yes |
| Wood or multi-fuel stove | Yes |
| Oil boiler | Yes |
| Gas cooker only | No |
| Decorative fireplace that does not work | No |
| Electric heating only | No |
Source: regulation 4 and the government Q&A booklet.[1][2] Place CO alarms at head height, 1 to 3 metres from the appliance.[2] Gas appliances also need their yearly gas safety check.[4]
Checks and repairs
The landlord checks that each alarm works on the day a new tenancy begins and repairs or replaces an alarm after the tenant reports it faulty.[1]
- Day one: test every alarm; one way to prove it is to have the tenant sign the inventory recording the test.[2]
- During the tenancy: tenants test the alarms; the landlord should show them how and share the instructions.[2]
- After a report: check and repair or replace the alarm as soon as reasonably practicable.[1]
- No access: write to the tenant, offer convenient times and keep a record of each attempt; you are not expected to go to court for access.[2]
Shared homes where the tenant lives with the landlord or the landlord’s family, long leases, student halls, hotels and care homes are excluded.[2]
Fire safety regulations for landlords beyond alarms
Alarms are one part of a landlord’s fire safety duties; the others are escape routes, safe furniture and extra rules for HMOs and flats.[5][6]
| Duty | What it means |
|---|---|
| Alarms | Smoke alarm on each storey; CO alarm by fixed combustion appliances (the rules above) |
| Escape routes | The tenant has access to escape routes at all times |
| Furniture and furnishings | Anything you supply is fire safe |
| Large HMO | Fire alarms and extinguishers; see the HMO licence rules |
| Flats | Follow the fire safety regulations for purpose-built blocks and houses converted into flats |
| Repairs | Fire safety issues are always the landlord’s repair |
Sources: GOV.UK guidance for tenants and landlords.[5][6] Fire hazards are also one of the risks a council checks under the housing health and safety rating system.[6]
Enforcement: remedial notice and £5,000 penalty
Councils enforce the alarm regulations with a remedial notice and a penalty of up to £5,000 per breach.[3][2] The notice gives you 28 days from service to fit, repair or check the alarms, and 28 days to make written representations.[3] The alarm check is one of the day-one items in the landlord checklist; the free landlord compliance calendar keeps the gas, EICR and EPC dates next to it.
Frequently asked questions
What do the smoke and carbon monoxide alarm regulations require?
The Smoke and Carbon Monoxide Alarm (England) Regulations 2015, amended from 1 October 2022, require a smoke alarm on each storey with living accommodation, a carbon monoxide alarm in each room with a fixed combustion appliance (not a gas cooker), a check on the first day of a new tenancy, and repair or replacement after a report.[1][2]
Do smoke alarms in a rental have to be hard-wired?
No. The regulations do not set the type. Government guidance recommends alarms that meet BS 5839-6, and sealed-for-life batteries rather than replaceable ones.[2]
What do the carbon monoxide alarm regulations say about gas boilers?
Who changes the batteries in a rented home?
Sources
- Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulation 4
- Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022: guidance for landlords and tenants
- Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulations 5 and 8 (remedial notice and penalty)
- Gas Safety (Installation and Use) Regulations 1998, regulation 36
- Private renting: your landlord’s safety responsibilities
- Renting out your property: landlord responsibilities